In order to determine the photometric measuring results accurately ProScan needs a camera with autofocus. This is the only way to determine the results with maximum precision. Not having one could prevent you from downloading the app from the store. Moreover the app requires the Android version 7.0 or higher or iOS 13.0 or higher. It is compatible with iPhone, iPad and iPod touch, as well as with 5100 Android smartphone and tablet types. If the download in the store doesn’t work, your mobile is probably incompatible with one of the above mentioned points. If there are any problems during use, e.g. with the scanning, please contact our customer service team: www.jbl.de/en/support .
The tests from the test range: JBL GH test, JBL KH test, JBL calcium test Ca and JBL magnesium test Mg, where the number of drops are counted until the colour changes and the counted value is multiplied by a value: _x000D_ _x000D_ GH = number of drops = general hardness in °dH _x000D_ _x000D_ KH = number of drops = carbonate hardness in °dH _x000D_ _x000D_ CO2 = number of drops * 2 = CO2 in mg/l _x000D_ _x000D_ Magnesium + calcium = number of drops * 120 = amount Ca + Mg in mg/l _x000D_ _x000D_ Calcium = number of drops * 20 = amount Ca in mg/l _x000D_ _x000D_ Magnesium = amount Ca+Mg from magnesium test - amount Ca in mg/l = magnesium in mg/l
Please clean the pane thoroughly before you install the thermometer. Algae, biofilms and lime can prevent it from sticking. If the thermometer still doesn’t hold, there may be a problem with the suction cup. Due to a material defect some suction cups have bubble-like excrescences which prevent a correct hold. If you own such a suction cup, please contact our customer service, and provide a photo.
The colour charts are intended to be used with the comparator block. In addition, when the comparator block is used with the blank water sample, this compensates the inherent water colour._x000D_ _x000D_ Therefore, if the comparator block is not used, there will most likely be deviations in the readings.
The reason is often an incorrect use of the test. It is important to shake the test vigorously for precisely one minute. All the other important steps can be read in the instructions.
JBL OxyPond is used to combat oxygen deficiency. Oxygen deficiency develops mainly during the winter under an ice cover, or during the summer in high temperatures. The oxygen content of water is temperature dependent. At a water temperature of 0°C the maximum oxygen content is 14.16 mg/l, whereas at a water temperature of 30°C it is only 7.53 mg/l.
After reinstallation the bubbles move only haltingly through the diffuser and sometimes merge into large bubbles. The device needs approx. 48 hours to set up! After that a bio-film will have formed on the surface of the device, allowing the bubbles to rise freely upwards. After the running in time the required bubble count will adapt itself for your aquarium.
Have you lost your record sheets, used them all up, or need them in another language? _x000D_ In the appendix of this FAQ you will find PDF files for printing them out in German, English and French.