JBL PROFLORA CO2 TAIFUN INLINE 19/26
In unserem FAQ‑Bereich findet ihr Antworten auf die am häufigsten gestellten Fragen. Solltet ihr hier nicht fündig werden, zögert bitte nicht, uns direkt zu kontaktieren – wir helfen euch gerne weiter.
If the bubble counter does not contain any water after installation, simply wait a few hours without switching on the CO2. It will fill itself through the water jet from the filter. Alternatively, the chamber of the bubble counter can be filled with water during installation.
In order to achieve a uniform bubble pattern with fine microbubbles, the modern ceramic-PE hybrid membrane should be watered before commissioning. If this is not done, large bubbles will form.
Please wait until sufficient pressure has built up in the CO2 hose. Alternatively, the CO2 supply can be increased significantly for a short time.
In line with the motto "better safe than sorry," some aquarium owners install several check valves in the same circuit. If you use the JBL PROFLORA direct inline diffuser or the JBL PROFLORA CO2 Count Safe bubble counter, for example, you already have an integrated check valve. If you use a separate check valve (JBL PROFLORA SafeStop) in addition, problems may arise when opening the check valves. This effect can be observed if the addition does not start again automatically after the night shut-off or interruption of the supply with the controller. Please note that, depending on the working pressure and the number of bubbles, it may take a few minutes between the start of the addition and the visible entry of CO2 into the aquarium. Each spring in a check valve requires a certain amount of pressure to open. Multiple springs can therefore interfere with each other and, depending on the distance between the two check valves, reduce the pressure on the spring to such an extent that it remains closed. Therefore, please always use only one check valve for your CO2 installation.
All check valves and backflow preventers from JBL require a working pressure of at least 0.6 bar for the valve to open. This feature is found in the JBL PROFLORA CO2 TAIFUN SAFESTOP, COUNTSAFE, and INLINE. The JBL PROFLORA TAIFUN diffusers also all work with this pressure. A higher working pressure is not necessary, which is why all accessories also work with the JBL PROFLORA BIO SETs (except JBL PROFLORA CO2 STARTER BIO SET). Depending on the installation, long hoses and other components may require a slightly higher working pressure than 0.6 bar, which is why the default setting of 1.2 bar is sufficient in all cases.
Stelle deine Frage an das JBL Service Team.